Category 1 · Materials, Chemicals, Microorganisms and Toxins · A · Systems, Equipment and Components

ECCN 1A007

Equipment and devices, “specially designed” to initiate charges and devices containing “energetic materials,” by electrical means, as follows (see List of Items Controlled).

NS — National SecurityNP — Nuclear NonproliferationAT — Anti-Terrorism
License Requirements · eCFR texteCFR 2026-11-09

Reason for Control

NS, NP, AT

Control(s) · Country Chart column

Control(s)Country chart (see Supp. No. 1 to part 738)
NS applies to entire entryNS Column 2
NP applies to 1A007.b, as well as 1A007.a when the detonator firing set meets or exceeds the parameters of 3A229NP Column 1
AT applies to entire entryAT Column 1

List Based License Exceptions (as published)

  • LVS: N/A
  • GBS: N/A

List of Items Controlled

Related Controls: High explosives and related equipment “specially designed” for military use are “subject to the ITAR” (see 22 CFR parts 120 through 130). This entry does not control detonators using only primary explosives, such as lead azide. See also ECCNs 0A604, 3A229, and 3A232. See 1E001 for “development” and “production” technology controls, and 1E201 for “use” technology controls.

Related Definitions: N/A

Items (6 lines)

a. Explosive detonator firing sets designed to drive explosive detonators specified by 1A007.b;

b. Electrically driven explosive detonators as follows:

b.1. Exploding bridge (EB);

b.2. Exploding bridge wire (EBW);

b.3. Slapper;

b.4. Exploding foil initiators (EFI).

Technical Notes: 1. The word initiator or igniter is sometimes used in place of the word detonator. 2. For the purposes of 1A007.b, the detonators of concern all utilize a small electrical conductor (bridge, bridge wire, or foil) that explosively vaporizes when a fast, high-current electrical pulse is passed through it. In non slapper types, the exploding conductor starts a chemical detonation in a contacting high explosive material such as PETN (pentaerythritoltetranitrate). In slapper detonators, the explosive vaporization of the electrical conductor drives a flyer or slapper across a gap, and the impact of the slapper on an explosive starts a chemical detonation. The slapper in some designs is driven by magnetic force. The term exploding foil detonator may refer to either an EB or a slapper-type detonator.

Country Chart row viewer

Shows the X marks in the columns this entry cites (Supplement No. 1 to Part 738) for one destination. It does not state a license conclusion.

Loading…

Source: https://www.ecfr.gov/api/versioner/v1/full/2026-11-09/title-15.xml?part=774. eCFR issue date 2026-11-09; last checked for a newer eCFR issue 2026-11-16. The eCFR is not the official legal edition of the CFR. Official tools: BIS Interactive CCL · SNAP-R (CCATS) · eCFR Supplement No. 1 to Part 774. Classification of your product is not provided here — see SNAP-R / CCATS.