Category 6 · Sensors and Lasers · A · Systems, Equipment and Components
ECCN 6A006
“Magnetometers”, “magnetic gradiometers”, “intrinsic magnetic gradiometers”, underwater electric field sensors, “compensation systems”, and “specially designed” “components” therefor, as follows (see List of Items Controlled).
Reason for Control
NS, AT
Control(s) · Country Chart column
| Control(s) | Country chart (see Supp. No. 1 to part 738) |
|---|---|
| NS applies to entire entry | NS Column 2 |
| AT applies to entire entry | AT Column 1 |
List Based License Exceptions (as published)
- LVS: $1500, N/A for 6A006.a.1; “Magnetometers” and subsystems defined in 6A006.a.2 using optically pumped or nuclear precession (proton/Overhauser) having a 'sensitivity' lower (better) than 2 pT (rms) per square root Hz; and 6A006.d, and 6A006.e.
- GBS: N/A
Special Conditions for STA
STA: License Exception STA may not be used to ship any commodity in: 6A006.a.1; or 6A006.a.2; or 6A006.c.1 “Magnetic gradiometers” using multiple “magnetometers” specified by 6A006.a.1 or 6.A006.a.2; or 6A006.d or .e (only for underwater receivers incorporating magnetometers specified in 6A006.a.1 or 6A006.a.2) to any of the destinations listed in Country Group A:6 (See Supplement No.1 to part 740 of the EAR).
List of Items Controlled
Related Controls: See also 6A996. This entry does not control instruments “specially designed” for fishery applications or biomagnetic measurements for medical diagnostics.
Related Definitions: N/A
Items (18 lines)
a. “Magnetometers” and subsystems, as follows:
a.1. “Magnetometers” using “superconductive” (SQUID) “technology” and having any of the following:
a.1.a. SQUID systems designed for stationary operation, without “specially designed” subsystems designed to reduce in-motion noise, and having a 'sensitivity' equal to or lower (better) than 50 fT (rms) per square root Hz at a frequency of 1 Hz; or
a.1.b. SQUID systems having an in-motion-magnetometer 'sensitivity' lower (better) than 20 pT (rms) per square root Hz at a frequency of 1 Hz and “specially designed” to reduce in-motion noise;
a.2. “Magnetometers” using optically pumped or nuclear precession (proton/Overhauser) “technology” having a 'sensitivity' lower (better) than 20 pT (rms) per square root Hz at a frequency of 1 Hz;
a.3. “Magnetometers” using fluxgate “technology” having a 'sensitivity' equal to or lower (better) than 10 pT (rms) per square root Hz at a frequency of 1 Hz;
a.4. Induction coil “magnetometers” having a 'sensitivity' lower (better) than any of the following:
a.4.a. 0.05 nT (rms)/square root Hz at frequencies of less than 1 Hz;
a.4.b. 1 × 10−3 nT (rms)/square root Hz at frequencies of 1 Hz or more but not exceeding 10 Hz; or
a.4.c. 1 × 10−4 nT (rms)/square root Hz at frequencies exceeding 10 Hz;
a.5. Fiber optic “magnetometers” having a 'sensitivity' lower (better) than 1 nT (rms) per square root Hz;
b. Underwater electric field sensors having a 'sensitivity' lower (better) than 8 nanovolt per meter per square root Hz when measured at 1 Hz;
c. “Magnetic gradiometers” as follows:
c.1. “Magnetic gradiometers” using multiple “magnetometers” controlled by 6A006.a;
c.2. Fiber optic “intrinsic magnetic gradiometers” having a magnetic gradient field 'sensitivity' lower (better) than 0.3 nT/m (rms) per square root Hz;
c.3. “Intrinsic magnetic gradiometers”, using “technology” other than fiber-optic “technology”, having a magnetic gradient field 'sensitivity' lower (better) than 0.015 nT/m (rms) per square root Hz;
d. “Compensation systems” for magnetic and underwater electric field sensors resulting in a performance equal to or better than the control parameters of 6A006.a, 6A006.b, and 6A006.c; and
e. Underwater electromagnetic receivers incorporating magnetic field sensors specified by 6A006.a or underwater electric field sensors specified by 6A006.b.
Technical Note: For the purposes of 6A006, 'sensitivity' (noise level) is the root mean square of the device-limited noise floor which is the lowest signal that can be measured.
Country Chart row viewer
Shows the X marks in the columns this entry cites (Supplement No. 1 to Part 738) for one destination. It does not state a license conclusion.
Loading…
Source: https://www.ecfr.gov/api/versioner/v1/full/2026-11-09/title-15.xml?part=774. eCFR issue date 2026-11-09; last checked for a newer eCFR issue 2026-11-16. The eCFR is not the official legal edition of the CFR. Official tools: BIS Interactive CCL · SNAP-R (CCATS) · eCFR Supplement No. 1 to Part 774. Classification of your product is not provided here — see SNAP-R / CCATS.